CNSAC Reusable EEG Cap for Adults with Sintered Ag/AgCl ElectrodesCNSAC Reusable EEG Cap for Adults with Sintered Ag/AgCl ElectrodesElectrode layout of the CNSAC 20-channel EEG cap with Ag/AgCl electrodes according to the international 10–20 system
CNSAC Reusable EEG Cap for Adults with Sintered Ag/AgCl Electrodes
CNSAC Reusable EEG Cap for Adults with Sintered Ag/AgCl Electrodes
Electrode layout of the CNSAC 20-channel EEG cap with Ag/AgCl electrodes according to the international 10–20 system

CNSAC Reusable EEG Cap for Adults with Sintered Ag/AgCl Electrodes

Item Number: EC-403
Normal price 319.00 EUR | Savings: -319.00 (Liquid error (sections/product-template line 227): divided by 0%)
/
Shipping costs will be calculated at checkout.

plus 19% VAT

0000
CNSAC Reusable EEG Cap for Adults with Sintered Ag/AgCl Electrodes

CNSAC Reusable EEG Cap for Adults with Sintered Ag/AgCl Electrodes

S (50–54 cm) - 319.00
  • S (50–54 cm) - 319.00
  • M (54–58 cm) - 319.00
  • L (58–62 cm) - 319.00
  • XL (62–66 cm) - 319.00

CNSAC Reusable EEG Cap for Adults with Sintered Ag/AgCl Electrodes

Description

The CNSAC Reusable EEG Cap for Adults with Sintered Ag/AgCl Electrodes was developed for reliable EEG recordings in clinical neurophysiology and neuroscience research. It is suitable for routine EEG, long-term EEG monitoring, and sophisticated neurophysiological examinations in adult patients.

The reusable CNSAC Ag/AgCl electrodes are characterized by high signal quality, excellent long-term stability, and low polarization. As a result, they enable stable and reproducible EEG recordings and are particularly well-suited for applications that require reliable signal recording over extended periods of time.

Thanks to the open electrode system, each individual electrode can be accessed directly throughout the entire recording. Electrodes with elevated impedance can be quickly optimized by reapplying conductive EEG paste or by making targeted adjustments to the electrode position, without having to remove the EEG cap.

Individual electrodes can be replaced as needed. This simplifies maintenance, extends the service life of the EEG cap, and reduces the effort required when electrodes are damaged or worn out. The lightweight and flexible backing material ensures a comfortable fit for adult patients and stable electrode positioning during the examination.

Available sizes: S, M, L, XL

Properties

  • EEG Cap for Adult Patients
  • Open electrode system for direct access to each electrode
  • Reusable CNSAC Ag/AgCl Electrodes
  • Sintered electrodes for high long-term stability
  • Low polarization for stable EEG recordings
  • High and consistent signal quality
  • Optimization of Individual Electrodes During Recording
  • Replaceable Individual Electrodes
  • Lightweight and comfortable stretch fabric
  • Stable and reproducible electrode positioning
  • Efficient Patient Preparation
  • Compatible with standard EEG systems via the CNSAC adapter cable
  • Compatible with the CNSAC disposable chin strap
  • Suitable for repeated clinical use and research applications

Areas of application

  • routine EEG
  • Clinical EEG
  • Long-Term EEG Monitoring
  • Epilepsy Diagnostics
  • Clinical Neurophysiology
  • Study of Brain Function
  • Polysomnography (PSG)
  • Sleep Medicine and Sleep Diagnostics
  • Neuroscience Research

Electrode Positions (20 Channels)

Channel Electrode position Region
1 Fp1 Left frontopolar
2 Fp2 Right frontopolar
3 F7 Front left
4 F3 Frontal left (medial)
5 Fz Center front
6 F4 Frontal right (medial)
7 F8 Front right
8 T3 Temporal links
9 C3 Center-left
10 Cz Center-center
11 C4 Center-right
12 T4 Temporal (right)
13 T5 Posterior temporal links
14 P3 Left parietal lobe
15 Pz Central parietal
16 P4 Right parietal lobe
17 T6 Right posterior temporal region
18 O1 Left occipital
19 O2 Right occipital
20 M1 Left mastoid/auricular electrode
21 M2 Right mastoid/auricular electrode



Additional integrated electrodes (not EEG channels)

Electrode Function
REF Reference electrode
GND Ground

 

Electrode Positions (10–20 System)

Search on our site