CNSAC Reusable 20-Channel EEG Cap with Ag/AgCl Electrodes for Adults on a Model HeadCNSAC Reusable 20-Channel EEG Cap with Connection Cable and Ag/AgCl ElectrodesAdults wear the CNSAC reusable 20-channel EEG cap for clinical EEG and sleep diagnosticsElectrode layout of the CNSAC 20-channel EEG cap with Ag/AgCl electrodes according to the international 10–20 system
CNSAC Reusable 20-Channel EEG Cap with Ag/AgCl Electrodes for Adults on a Model Head
CNSAC Reusable 20-Channel EEG Cap with Connection Cable and Ag/AgCl Electrodes
Adults wear the CNSAC reusable 20-channel EEG cap for clinical EEG and sleep diagnostics
Electrode layout of the CNSAC 20-channel EEG cap with Ag/AgCl electrodes according to the international 10–20 system

CNSAC Reusable EEG Cap for Adults – 20 Channels

Item Number: EC-204
Normal price 269.00 EUR | Savings: -269.00 (Liquid error (sections/product-template line 227): divided by 0%)
/
Shipping costs will be calculated at checkout.

plus 19% VAT

0000
CNSAC Reusable 20-Channel EEG Cap with Ag/AgCl Electrodes for Adults on a Model Head

CNSAC Reusable EEG Cap for Adults – 20 Channels

S (50–54 cm) - 269.00
  • S (50–54 cm) - 269.00
  • M (54–58 cm) - 269.00
  • L (58–62 cm) - 269.00
  • XL (62–66 cm) - 269.00

CNSAC Reusable EEG Cap for Adults – 20 Channels

Description

TheCNSAC Reusable 20-Channel EEG Cap for Adults was developed for comprehensive routine EEG examinations, long-term EEG monitoring, and advanced neurophysiological diagnostics in adult patients. Equipped with reusable CNSAC Gold Cup electrodes, it ensures excellent signal quality, reproducible electrode placement, and efficient patient preparation.

Thanks to the open electrode system, each individual electrode can be accessed throughout the entire recording. Electrodes with increased impedance can be quickly optimized by refilling them with conductive EEG paste or by making targeted adjustments to the electrode position, without having to remove the EEG cap. Damaged electrodes can be replaced individually, thereby extending the cap’s service life and reducing maintenance costs.

The EEG cap features 20 recording channels, A1 and A2 reference electrodes, two integrated replacement leads, and two dummy sockets for easy replacement of individual electrodes. The lightweight, elastic fabric ensures a secure fit and high comfort—even during longer EEG and PSG examinations.

Available sizes: S, M, L, XL

Properties

  • Open electrode system for maximum flexibility
  • 20 EEG recording channels
  • A1 and A2 Reference Electrodes
  • Reusable CNSAC Gold Cup Electrodes
  • Direct access to each electrode during the recording
  • Optimizing individual electrodes without removing the hood
  • Replaceable electrodes for a longer product life
  • Two built-in replacement cables
  • Two blind sleeves for electrode replacement
  • Lightweight and comfortable stretch fabric
  • Stable and reproducible electrode positioning
  • Reduced preparation time
  • Compatible with standard EEG systems via the CNSAC adapter cable
  • Compatible with the CNSAC disposable chin strap
  • Suitable for repeated clinical use

Areas of application

  • routine EEG
  • Clinical EEG
  • Long-Term EEG Monitoring
  • Epilepsy Diagnostics
  • Clinical Neurophysiology
  • Study of Brain Function
  • Polysomnography (PSG)
  • Sleep Medicine and Sleep Lab
  • Neuroscience Research

Electrode Positions (20 Channels)

Channel Electrode position Region
1 Fp1 Left frontopolar
2 Fp2 Right frontopolar
3 F7 Front left
4 F3 Frontal left (medial)
5 Fz Center front
6 F4 Frontal right (medial)
7 F8 Front right
8 T3 Temporal links
9 C3 Center-left
10 Cz Center-center
11 C4 Center-right
12 T4 Temporal (right)
13 T5 Posterior temporal links
14 P3 Left parietal lobe
15 Pz Central parietal
16 P4 Right parietal lobe
17 T6 Right posterior temporal region
18 O1 Left occipital
19 O2 Right occipital
20 M1 Left mastoid/auricular electrode
21 M2 Right mastoid/auricular electrode



Additional integrated electrodes (not EEG channels)

Electrode Function
REF Reference electrode
GND Ground

 

Electrode Positions (10–20 System)

Search on our site