PRODUCTS

CNSAC Silver/silver chloride (Ag/AgCl) Cup Electrodes, 150 cm cable length (60″), 10 pcs.

$130.80

150 cm cable length (60″)

10 mm diameter (∅)

1.5mm female DIN42802 connector (touchproof )

Color-coded cables (10 colors)

Highly flexible and biocompatible cable

Quantity:

Description

Reusable Silver/silver chloride (Ag/AgCl) Cup Electrodes, EEG Electrodes

 

Ag/AgCl Cup Electrodes with highly flexible wire for EEG and PSG applications

 

Recommended to be use in combination with lic2 adhesive conductive Electroce cream lic2® Electrode Cream, 10 tubes x 100g

 

  • 150 cm cable length (60″)
  • 10 mm diameter ()
  • 1.5mm female DIN42802 connector (touchproof)
  • Color-coded cables (10 colors)
  • Highly flexible wire for easy application, cleaning and disinfection
  • Ultra low noise wire
  • 10 pcs.

 

 

Specification Data

  • Diameter of cup                                 10 mm
  • Hight of cup                                        2.8 mm
  • Lead-free                                                ✓
  • Latex-free                                              ✓
  • BPA-free lead wire                             ✓
  • DEHP-free lead wire                         ✓
  • RoHS compliant                                   ✓
  • Lead wire isolation                            Biocompatible TPU
  • Lead wire core                                     Kevlar
  • Lead wire design                                 Tinsel wire
  • Electrode                                                Silver plated with silver chloride
  • Connector                                              DIN 42802
  • Connector material                           Medical grade PVC

 

 

Electrical Data

  • AC impedance                                     ≤ 0.15 kΩ·cm2
  • DC offset voltage                                ≤ 2mV
  • Potential drift                                       ≤ ± 0.1mV/10min
  • Conduction Resistance                    ≤ 5Ω

 

 

Packaging Data

  • Pack                                                   Set of 10, assorted colors  (red, yellow, green, blue, orange, brown, violet, grey, black, white)
  • Connector color                          Grey

 

Storage Data

  • Temperature                                           10 – 50 °C (at room temperature)
  • Humidity                                                   20 – 80 %
  • Atmospheric Pressure                       87 kPa – 108 kPa
  • Additional conditions                        No corrosive gas and well-ventilated

 

Operating Data

  • Shelf life                                                  Three years
  • Period of use                                         6 months in average, but more than 1-year lifetime can be achieved in case of correct and expert application
  • Connector plugging times             5000 times

 

Cleaning and Disinfection:

(1) Clean the head skin (if washing the head, use alcohol or scrub cream to clean partly).

(2) Use the electrode plate to take proper conductive paste and put to the present location.

(3) Connect the pin of the lead to device.

(4) Start recording.

(5) After finishing the record, help patient to clean their head skin.

(6) Clean the electrode with clean water or warm water (around 40℃) and

immerse for max 30mins, do not immerse for a long time. Do not immerse into any

disinfectant or hot water. Do not use ultrasound to clean the electrodes.

(7) Air-dry and standby.

 

Available variants:

75 cm (30″), 100 cm (40″), 200 cm (80″) and 250 cm (98″)

 

 

Compatibility:

CNSAC Silver/silver chloride (Ag/AgCl) Cup Electrodes 100cm are compatible to all medical instruments with an 1.5 mm input socket including but not limited to:

  • Compumedics
  • Embla
  • Somnomedics
  • Natus
  • Cadwell
  • Bio-logic
  • Compumedics
  • Embla
  • Grass
  • Xltek
  • Lifelines
  • Nicolet
  • NicoletONE
  • Nihon Kohden
  • Respironics
  • Teca Nervus

 

Instructions for use & data sheet for download:

Simply click on the following picture to download the instructions for use and the data sheet for the silver/silver chloride (Ag/AgCl) cup electrodes.

instructions for use & data sheet for silver/silver chloride (Ag/AgCI) cup electrodes

Tutorial: How to attach EEG electrodes:

Learn how to attach Cup Electrodes with our tutorial video in easy steps.

YouTube

Mit dem Laden des Videos akzeptieren Sie die Datenschutzerklärung von YouTube.
Mehr erfahren

Video laden